DMP OSCATOR ADP                                                                                             DMP OSCATOR ADP







                 Instruction manual




                 Use


                 Connect a mono audio output into the “Input” and the
                 oscilloscope will immediately start measuring.
                 There are 4 buttons. The “Hold” button freezes the
                 screen. The “Up” and “Down” buttons can be used for
                 setting the range for frequency timing  and voltage
                 range adjustment. With the “Select” button you can
                 choose whitch meachure range you want to change.



                 Measuring


                 At the top of the display you will find the measure
                 range for Voltage, Frequency Timing , Trigger
                 Direction, RMS Voltage indication, Frequency
                 measuring and average. On the left you will find the
                 positive and negative voltage scale measurement.
                                                                                                                            Front                    Side
                                                                                                                            (Aluminum matt anodised)

                 Set schedule                                                                                                                                                              Oscilloscope DMP
                                                                                                                                                                                           Oscator ADP 2021
                 You can adjust the Voltage, Timing and Trigger by
                 pressing the “Select” button. The underlined values at
                 the top of the display, indicates that it can be adjusted
                 by pressing the “Up” or ”Down” buttons.  Set the range
                 to maximize visibility for a clear and accurate reading.                                                                                                                  Example measurements



                 Zero adjustment function


                 If the waveform is not exactly at zero, it is possible to
                 calibrate it to its zero point. Press “HOLD” to pause the
                 waveform display, then press “SELECT” to auto-zero.
                 The waveform fits to the zero position and is stored in
                 the memory.



                                                                                                             ➥                                                                                                           ➥